Hotline 1 : 0822-5102-2483 Hotline 2 : 0857-7556-1612 (Marketing Team) Hotline 3 : 0812-8847-8408
IMG-LOGO

Sound Level Meter with Wifi

Kondisi : NEW

View : 129

ORDER NOW !!
Hotline 1 : 0822-5102-2483
Hotline 2 : 0857-7556-1612 (Marketing Team)
Hotline 3 : 0812-8847-8408

Banking on the skills of our qualified team of professionals, we are involved in manufacturing and exporting Sound Level Meter with Wifi. Using the instruments could not be simpler. The simple user interface can easily be scrolled and selected to immediately display the information you need. The keypad also has a dedicated dB Range key, simply press and then selects your required range. It measures the noise of a person with the help of wifi.

Applicable Standards

  • IEC 61672-1:2013
  • IEC 61260-1:2014 (Where Octave Bands Fitted)
  • IEC 61252:1993 amendment 1:2000 (Where Exposure Fitted)

 

Microphone

  • Class 1: Type 1 Pre-Polarized ½” (13.2 mm) Electrets Condenser Microphone -27 dB ± 2 dB re 1V/Pa
  • Class 2: Type 2 Pre-Polarized ½” (13.2 mm) Electrets Condenser Microphone –32 dB ± 3 dB re 1V/Pa
  • Measurement Ranges: Linear Operating Range: 95dB
  • Noise Floor: Typical ’A’ Weighting <15 dB (A) RMS
  • 'C' Weighting <18 dB(C) RMS
  • 'Z' Weighting <18 dB(Z) RMS
  • Frequency Weightings: Measurement 1: A, C or Z, Measurement 2: A, C or Z
  • Frequency Range: 1 Hz - 20 kHz (electrical characteristics)
  • Class 1: 12.5 Hz - 20 kHz (including microphone)
  • Class 2: 12.5 Hz - 16 kHz (including microphone)
  • Time Weighting:
  • Measurement 1: Slow, Fast, Impulse
  • Measurement 2: Slow, Fast, Impulse
  • Display: 2.4” Full Color TFT 240x320 pixels
  • Dual Measurements: Simultaneous dual measurement with independent time and frequency weightings.

 

Measurement Parameters


dBAir Safety: 
LSPL, LEQ, LMAX, LMAX, Peak, LEP’d, Exposure Points, Dose, Hearing Protector Calculator 

dBAir Safety Octave:
LSPL, LEQ, LMAX, LMAX, Peak, LEP’d, Exposure Points, Dose, Hearing Protector Calculator 
1/1 or 1/3 Octaves: 
LSPL, LEQ, LMAX, LMAX, Peak 

dBAir Environmental:
LSPL, LE, LEQ, LMAX, LMAX, Peak, Ltm3, Ltm5, Lday, Lnight, Ldn, Lden, NA, 10 user-definable Ln values (pre-set to: L1, L2, L5, L10, L50, L90, L95, L98, L99) plus LAF* for Noise act assessment. 

dBAir Environmental Octave:
LSPL, LE, LEQ, LMAX, LMAX, Peak, Ltm3, Ltm5, Lday, Lnight, Ldn, Lden, NA, 10 user-definable Ln values (pre-set to: L1, L2, L5, L10, L50, L90, L95, L98, L99) plus LAF* for Noise act assessment. 
1/1 or 1/3 Octaves: 
LSPL, LE, LEQ, LMAX, LMAX, Ln’s, Peak 

Marketing