Hotline 1 : 0822-5102-2483 Hotline 2 : 0857-7556-1612 (Marketing Team) Hotline 3 : 0812-8847-8408
IMG-LOGO

DCC Dual Channel Controller

Category : Controllers

Kondisi : NEW

View : 129

ORDER NOW !!
Hotline 1 : 0822-5102-2483
Hotline 2 : 0857-7556-1612 (Marketing Team)
Hotline 3 : 0812-8847-8408

The DCC Dual Channel Controller is a comprehensive and dependable, self-contained system that offers one or two channel configurations for monitoring toxic and combustible gases and PID TVOCs with straight-forward control functionality for non-hazardous, non-explosion rated, commercial and light industrial applications. Sensor configurations include, two internal electrochemical sensors (one must be CO), or one internal electrochemical and one remote catalytic or PID sensor or a remote 4-20 mA transmitter. Field configurable settings are done through an easy to navigate, comprehensive menu structure. Other features include two 4 - 20 mA outputs that can be used for VFD control, one configurable 4 - 20 mA input, two alarm level line voltage, two SPDT dry contact relays with field configurable time delays and trigger levels, a field selectable integral audible alarm and an LCD display with LED indicators for channel alarm status and fault conditions. Automated calibration and other maintenance procedures are simple and easily performed in the field. For parking garage applications, our proprietary Calibration Extending Firmware (CEF) takes into account the aging of the toxic gas sensors so that less frequent calibrations are required. The DCC is the big brother to the SCC and offers more features and gas sensor choices.

Key Features

  • Single or dual channel operation
  • Flexible internal and/or remote sensor configurations
  • 2 line by 16 character LCD display with LED indicators
  • Two dry contact relays, 5-amps @240 volts each
  • Two 4-20 mA outputs, can be use for VFD control
  • One configurable 4-20 mA input
  • Line Voltage (90-240 VAC) or Low Voltage (24 VAC/VDC)
  • Door mounted audible alarm, optional water tight version or extra loud version available
  • Standard water / dust tight, corrosion resistant enclosure (drip proof); IP54 rated with water tight, door mounted audible alarm installed

 

Specifications

Target Gas

Gas Sensors

Carbon Monoxide (CO), Nitrogen Dioxide (NO2), Nitric Oxide (NO), Oxygen (O2), Hydrogen Sulphide (H2S), Ethylene (C2H4), Sulphur Dioxide (SO2), Hydrogen (H2), Methane (CH4), Propane (C3H8), TVOCs

Mechanical

Enclosure

ABS / Polycarbonate, corrosion resistant

Copper coated interior to reduce RF interference

IP54 rated with optional splash guard installed

Weight

1.18 kg / 2.6 lbs

Size

254 x 226 x 113 mm / 10.0 x 8.9 x 4.44 inches

User Interface

Display

2x16 character LCD display
LED indicators for “CH1" state, "CH2" state and “FAULT”

LED indicators for "CH1" state, "CH2" state and "FAULT"

Input/Output

SILENCE Push Button

Temporarily clears buzzer / latched relays

Input

4-20 mA analog

Output

4-20 mA analog

Relay

Two internal SPDT dry contact relays rated 5 amps @ 240 VAC

Audible Alarm

Standard internal buzzer, rated 76 dB @ 3 m (10 ft)

Optional: door mounted, water tight buzzer, rated 85 dB @ 60.96 cm (2 ft)

Optional: loud, door mounted buzzer, rated 90 dB @ 30 cm (1 ft)

Electrical

Power Requirement

Low Voltage: 16-30 VDC or 12-30 VAC, 10 W Class 2

Line Voltage: 90 – 240 VAC, 50 -60 Hz

Wiring

Low Voltage: 24 VDC or 24 VAC 2-conductor shielded minimum 18 AWG stranded within conduit

Line Voltage: VAC 3-conductor shielded minimum 18 AWG stranded within conduit

Distance

Maximum 61 m / 200 ft between controller and ESH-A Remote Sensor using minimum 18 AWG stranded within conduit

Fuses

Thermal, resetting

Environmental

Operating Temperature

-20°C to 40°C (-4°F to 104°F)

with internal heater

-40°C to 40°C (-40°F to 104°F)

Operating Humidity

15 - 90% RH non-condensing

Certifications

Conforms to:

CSA-C22.2 No. 205-M1983 (R2009), UL508 (Edition 17):2007

EMC Directive 2004/108/EC, EN 50270:2006, Type 1, EN61010

FCC. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

RoHS compliant circuit boards

 

Marketing
Teknisi