Hotline 1 : 0822-5102-2483 Hotline 2 : 0857-7556-1612 (Marketing Team) Hotline 3 : 0812-8847-8408
IMG-LOGO

Portable Combustion Analyzer (PCA3)

Category : Gas Detection

Kondisi : NEW

View : 129

ORDER NOW !!
Hotline 1 : 0822-5102-2483
Hotline 2 : 0857-7556-1612 (Marketing Team)
Hotline 3 : 0812-8847-8408

This PCA®3 lightweight handheld instrument is widely used by busy technicians and boiler contractors who need to ensure safe operating conditions, determine combustion efficiency and perform emissions test. In addition to the included Oxygen (O2) and Carbon Monoxide (CO) sensors, the PCA®3 can be ordered with CO (high), Nitric Oxide (NO), Nitrogen Dioxide (NO2) and Sulfur Dioxide (SO2) sensors or the sensors can be added in the field without down time, using the B-Smart® pre-calibrated sensor options.

Specifications

Measurement Ranges

  • Primary/Ambient Air Temperature: -4° to 999°F
  • Stack Temperature: -4° to 2192°F
  • Oxygen: 0 to 20.9%
  • Carbon Monoxide (H? Compensated): 0 to 4,000 ppm
  • Carbon Monoxide, (High Range): 4,001 to 20,000 ppm
  • Nitric Oxide: 0 to 3,000 ppm
  • Nitrogen Dioxide: 0 to 500 ppm
  • Sulfur Dioxide: 0 to 5,000 ppm
  • Pressure/Draft:    -72 to +72 inwc

Calculated Ranges

  • Combustion Efficiency: 0.1 to 100%
  • Excess Air: 1.0 to 250%
  • Carbon Dioxide (Dry Basis): 0 to Fuel Dependent Maximum
  • NOx (NO + NO2): 0 to 3,500 ppm
  • NOx referenced to % O2: 0 to 9,999 ppm
  • CO referenced to % O2: 0 to 9,999 ppm
  • NO referenced to % O2: 0 to 9,999 ppm
  • NO2 referenced to % O2: 0 to 9,999 ppm
  • SO2 referenced to % O2: 0 to 9,999 ppm

Accuracy

  • Oxygen: ± 0.3% O2 (Flue Gas)
  • Stack or Flue Gas Temperature:

o    ± 4°F between 32 and 255°F (± 2°C between 0 and 124°C)

o    ± 6°F between 256 and 480°F (± 3°C between 125 and 249°C)

o    ± 8°F between 481 and 752°F (± 4°C between 250 and 400°C)

  • Primary-air/Ambient Temperature:

o    ± 2°F between 32 and 212°F

o    (± 1°C between 0 and 100°C)

  • Pressure/Draft:

o    ± 2% Reading or 0.02 inwc -1 to 10 inwc

o    ± 3% of Reading between ± -40 and ± 40 inwc

  • CO:

o    ± 5% of Reading or ± 10 ppm in the range of 0-2000 ppm CO

o    ± 10% of Reading between 2001 to 4,000 ppm

  • NO: ± 5% of Reading or ± 5 ppm whichever is greater between 0 to 2000 ppm NO
  • NO: ± 5% of Reading or ± 5 ppm whichever is greater between 0-500 ppm NO2
  • SO2 : ± 5% of Reading or ± 10 ppm whichever is greater between 0-2000 ppm SO2

Logged Memory

  • 500 Complete Combustion Test Records

Selectable Fuels

  • Natural Gas, Oil #2, Oil #4, Oil #6, Propane, Coal, Wood, Kerosene, Bagasse and Digester Gas

Size

  • 9"H x 3"W x 2.5" (22.9 cm x 7.6 cm x 6.3 cm)

Power Source

  • 4 Disposable AA Alkaline Batteries. Optional Universal AC Adapter (100 to 240 Volts at 47 to 63 Hz)

Display

  • Full Color Graphic Display (320 x 240 pixels)

Warm Up Time

  • 60 Second Total Warm Up Time (sensors are checked and autozeroed during warm up)
Marketing
Teknisi