Hotline 1 : 0822-5102-2483 Hotline 2 : 0857-7556-1612 (Marketing Team) Hotline 3 : 0812-8847-8408
IMG-LOGO

Seismograph (The Mini-Seis)

Category : Vibration Monitoring

Kondisi : NEW

View : 129

ORDER NOW !!
Hotline 1 : 0822-5102-2483
Hotline 2 : 0857-7556-1612 (Marketing Team)
Hotline 3 : 0812-8847-8408

The Mini-Seis is the very definition of a great seismograph for an affordable cost. It is ideal for all kinds of blast vibration monitoring and for most continuous vibration monitoring in bargraph mode. Rugged, reliable and very easy to use, the Mini-Seis sets the standard for value in a seismograph.

Features

  • Lightweight and easy to use.
  • Rugged aluminum case shielded against interference.
  • Keypad and display for easy setup and data review.
  • Transducer and microphone interchangeable between units of like gain.
  • Variable recording ranges, trigger levels and record durations.
  • Rechargeable internal battery with typical 10 day continuous operation on a full charge.
  • Extended operation using AC power or external DC power.
  • The most powerful, yet easy to use, analysis software available

 

 

Application

  • All types of commercial blasting
  • Building implosions
  • Seismic exploration
  • Pile driving
  • Hoe ramming
  • Heavy equipment
  • Ordinance destruction

Specifications

Data Recorded                                     One (1) acoustic and three (3) seismic channels. 

Frequency Response                         Mini-Seis: 2 to 500 Hz. (-3 dB. points) at 2048 samples per second. 

                                                                  Lower sample rates reduce the high frequency response

                                                                  proportionately. 

                                                                 Mini-Seis II: 2 to 250 Hz. (-3 dB points) at 1024 samples per second. 

Seismic Sensors                                 Three component mounted velocity geophones or accelerometers,

                                                                 depending on the ordered recording ranges. 

Microphone                                           Ceramic element rated to at least 160 dB. 

Memory                                                 Solid state with all summary, setup, and recorded data retained

                                                                 with power off.

                                                                 A lithium backup battery retains data if primary power fails. 

Clock                                                      A 24 hour clock maintains the date and time accurate to within

                                                                 1 minute per month, even if primary power fails. 

Timer Mode                                           Allows an instrument to be active only during selected hours

                                                                 on a daily basis. 

Display                                                  The high contrast LCD has two lines of 40 characters to facilitate

                                                                the instrument's setup. It also allows the operator to view operating 

                                                                parameters and summary data. 

Optional Keypad                                 Contains 6 keys for entering setup data and operating commands. 

Power on Log                                       A log of the last 64 on/off cycles is kept in memory to indicate the

                                                                active monitoring periods.

                                                                If the timer is used, the log is updated each time it activates. 

Battery                                                   Internal 6 volt rechargeable. 

Operating Time                                    With a fully charged battery all models will operate from 7 to 10

                                                                 days at 1024 samples per sec. Longer times may be obtained

                                                                 using the timer mode or external power from a small solar cell 

                                                                 or automobile battery. 

External Battery Life                           A standard automobile battery will keep the internal battery at full

                                                                  charge for several months at moderate temperatures. If the external

                                                                  battery fails, the unit will continue to operate on its internal battery.

Charging                                                 An internal charging circuit allows charging with the supplied plug-in

                                                                  wall mount charger or any 10 to 15 volt DC supply.

                                                                  Power supplies for international use are available. 

Operating Temperature                      0 to 130 degrees F (-18 to 54 degrees C) 

Case                                                        Heavy gauge aluminum for effective electrical shielding and

                                                                  rugged protection. A stainless steel case is optional.

                                                                  The case is sealed allowing shallow burial. 

Size                                                          Approximately 7.5 in. x 4.5 in. x 2.5 in. 

Weight - Aluminum Case                    Approximately 3.5 lbs. (1.6 Kg.) without accessories. 

Weight - Stainless Steel                     Adds 2 lbs. (.9 Kg.) above the aluminum case weight. 

Weight - Accessories                         Approximately 6 lbs. (2.7 Kg.) including the storage case. 

Waveform Data                                    Mini-Seis: The full waveform signature is stored in solid state

                                                                  memory for up to 340 events. 

                                                                 Mini-Seis II 1/8M: Approximately 10 to 20 typical blast events. 

                                                                 Mini-Seis II 1/4M: Approximately 50 to 100 typical blast events. 

                                                                 Mini-Seis II 1/2M: Approximately 150 to 250 typical blast events. 

Summary Data                                     Summarized data include the event time, date, battery voltage,

                                                                 peak measurements, unit serial number and frequencies.

                                                                 The summarized data are stored in solid state memory

                                                                 for the last 341 events. 

Sample Rate                                         Mini-Seis: From 2048 samples per second per channel down to

                                                                 32 samples per second per channel. 

                                                                Mini-Seis II: 1024 or 512 samples per second per channel. 

Recording Units                                  English (U.S.) or metric. 

Seismic Recording Ranges             Standard (x2) 

                                                                 0.005 IPS to 2.5 IPS (0.125 to 64 MMPS) 

                                                                 0.01 IPS to 5.0 IPS (0.25 to 127 MMPS) 

                                                                 0.02 IPS to 10.0 IPS (0.50 to 254 MMPS) 

                                                                Optional (x1 - accelerometers) 

                                                                 0.01 IPS to 5.0 IPS (0.25 to 127 MMPS) 

                                                                 0.02 IPS to 10.0 IPS (0.50 to 254 MMPS) 

                                                                 0.04 IPS to 20.0 IPS (1.00 to 508 MMPS) 

                                                               Optional (x4) 

                                                                0.0025 IPS to 1.2 IPS (0.063 to 30.5 MMPS) 

                                                                0.005 IPS to 2.5 IPS (0.125 to 64 MMPS) 

                                                                0.01 IPS to 5.0 IPS (0.25 to 127 MMPS) 

                                                               Optional (x8) 

                                                                0.0013 IPS to 0.6 IPS (0.033 to 15.2 MMPS)

                                                                0.0025 IPS to 1.2 IPS (0.063 to 30.5 MMPS) 

                                                                0.005 IPS to 2.5 IPS (0.125 to 64 MMPS) 

Acoustic Ranges                                0.02 to 2.56 millibars (100 to 142 dB) 

                                                                0.04 to 5.12 millibars (106 to 148 dB). 

Trigger Levels                                    Seismic 

                                                               2.5 IPS Range - 0.01 to 0.57 IPS (0.25 to 14.5 MMPS). 

                                                               5.0 IPS Range - 0.02 to 1.14 IPS (0.5 to 29 MMPS). 

                                                              10.0 IPS Range - 0.04 to 2.28 IPS (1.0 to 58 MMPS). 

                                                              Seismic trigger sensitivities are proportionally modified by optional 

                                                             gains. 

                                                              Acoustic - 106 to 142 dB or 112 to 148 dB. 

Manual Trigger                                 Allows triggering from the keyboard or by an external input. One unit 

                                                             may be used to trigger additional instruments. 

Record Duration                              Mini-Seis: From 1 to 6 seconds at a sample rate of 2048 samples 

                                                             per second.

                                                             At lower sample rates, the duration is automatically increased

                                                             proportional to the amount of decrease in the sample rate. 

                                                             Mini-Seis II: From 1 to 9 seconds at 1024 samples per second. 

Cycle Time                                         Mini-Seis: At 1024 samples per second, up to 12 seconds of data 

                                                               can be taken with only 50 milliseconds between events.

                                                              After 12 seconds of data are stored, another event cannot be

                                                              taken until the previous data have been processed.

                                                              Processing requires about 3 seconds per second of recording time. 

                                                              Mini-Seis II: Maximum continuous data time is 9 seconds. 

Records Stored                                 Up to 341 typical coal mine or quarry blast events. 

Calibration Test (Seismic)              A dynamic transducer test is performed automatically after each 

                                                               event or manually on command. The test is stored in the summarized

                                                               data and may be downloaded as an event. 

Calibration Test (Acoustic)            An electronic test of the microphone is performed with the seismic test

                                                              and is stored in memory along with the seismic test. 

84 Hour Cal Test                               In a remote installation, an automatic calibration test occurs if no event

                                                               has been recorded for 84 hours. 

RS232 Serial Port                             Data can be downloaded and setup commands can be uploaded 

                                                               directly by computer or remotely by modem. 

Baud Rate                                           From 1200 to 38.4K. 

Marketing
Teknisi