The RLY-4 and RLY-8 are remote relay devices that offer up to four and eight (respectively) additional SPDT dry contact relays to a fixed gas detection system. The RLY-4 is specifically designed to communicate with both the QCC Quad Channel Controller and the FCS Flexible Control System via Modbus® communications protocol. The RLY-8 is designed to work with the FCS and FCS-8 only. In the event that the connection is lost between the controller and the remote relay, a user configurable default state can be set to ensure the relays continue to operate as required. The relays are rated 5 amps @ 240 VAC each and can be used to control remote alarms, strobes, exhaust fan starters, make up air fan contactors, etc. Both devices come in a standard water / dust tight, corrosion resistant ABS / polycarbonate enclosure with a hinged, secured door.

Key Features

  • Increases the number of available relays
  • User selectable gas alarm activation level for each relay (set at the controller)
  • User selectable “Failsafe” and latching operation (set at the controller)
  • ON/OFF Delay configurations (set at the controller)
  • User configurable to revert to a default state if connection is lost with the controller (set at the controller)
  • Modbus® RS-485 RTU communication
  • Standard water / dust tight, corrosion resistant enclosure

Specifications

Mechanical

Enclosure

ABS / Polycarbonate, corrosion resistant

Copper coated interior to reduce RF interference

Weight

RLY-4: 1.08 kg / 2.4 lbs

RLY-8: 1.24 kg / 2.75 lbs

Size

254 x 218 x 109 mm / 10.0 x 8.6 x 4.3 inches

Input/Output

Relay

RLY-4: 4 SPDT relays, rated 5 amps @ 240 VAC

RLY-8: 8 SPDT relays, rated 5 amps @ 240 VAC

Communication

Modbus® RS-485 RTU

Electrical

Power Requirement

24 VDC, 3W, Class 2 (24 VDC supplied by the Controller)

Wiring

4-conductor shielded minimum 18 AWG stranded within conduit

Fuses

Thermal, resetting

Environmental

Operating Temperature

-20°C to 40°C (-4°F to 104°F)

Operating Humidity

15 - 90% RH non-condensing

Certifications

Conforms to:

CSA-C22.2 No. 205-12, UL508 (Edition 17):2007

EMC Directive 2004/108/EC, EN 50270:2006, Type 1, EN61010

FCC. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

RoHS compliant circuit boards

 